Philippine Electrical Code Historical Background Intention Why do Code Rules Change? Purpose The primary objective of the code is to. Coyle, Daniel. The talent code: Greatness isn't born. It's grown. Here's how. / Daniel Coyle. p. cm. Includes bibliogr Philippines. Pages·· MB· Purpose of P.E.C. 1. Practical Safeguarding 2. Adequacy - This Code contains provisions that are considered minimum requirements.


PHILIPPINE ELECTRICAL CODE 2009 PDF DOWNLOAD

Author: Veronica Walsh
Country: Thailand
Language: English
Genre: Education
Published: 7 November 2017
Pages: 115
PDF File Size: 6.79 Mb
ePub File Size: 30.56 Mb
ISBN: 174-9-79071-252-6
Downloads: 56225
Price: Free
Uploader: Veronica Walsh

PHILIPPINE ELECTRICAL CODE 2009 PDF DOWNLOAD


No dwelling unit is supplied by more than one feeder.

PEC 2009 Reviewer

Each dwelling unit is equipped with electric cooking equipment. For volts, nominal, or less 1. Longer than 15m — 8.

PHILIPPINE ELECTRICAL CODE 2009 PDF DOWNLOAD

For over volts 1. Open Individual Conductors — 14 mm2 copper and 22 mm2 aluminum 2.

Philippine Electrical Code Part 1 - Filipino Engineers Wiki

Conductors in Cable — 8. Overhead Service Locations 1. Equipped with rain-tight service head. Located above the point of attachment of the service-drop conductors.

Drip loops formed on individual conductors to prevent moistures. Arranged that water will not philippine electrical code 2009 service raceway or equipment.

Philippine Electrical Code Reviewer | PEC Reviewer

Overhead Service Drop Conductors — The minimum size of overhead service drop conductors: And, at electric service entrance to buildings, also at the lowest point of the drip loop. Clearances from Buildings for Conductors of Not Over Volts, Nominal a Above Roofs — Shall not be less than mm above roof surface and maintained at a distance not less than mm in all directions from the edge of the roof.

Clearance from Windows — Shall be kept not less than mm. Vertical Clearance — mm measured horizontally of, platforms or philippine electrical code 2009. Building Openings — Overhead branch circuits shall not be installed beneath openings through which materials may be moved. Zone for Fire Ladders — A clear space zone at least mm wide left adjacent of the building to facilitate rising of philippine electrical code 2009 when necessary for fire fighting.

Philippine Electrical Code by kit kester lapitan on Prezi

Fire pumps high pressure for the building 2. Legally required standby systems 4. Optional standby systems 5. Parallel power production systems 6.

Multiple sources of supply for the purpose of enhanced reliability b Special Occupancies — By special permission, additional feeder or branch circuit shall be permitted: Multiple-occupancy buildings where there is no available space for service equipment accessible to all philippine electrical code 2009.

Where there is no terminal box, meter, or other enclosure, the point of connection is considered to be the point of entrance of the service conductors into the building.

Clearance of Service Lateral: Multi-conductor cable shall not be smaller than 8. Maximum Number of Disconnects — Shall consists of not more than 6 switches or sets of circuit breakers, or a combination thereof philippine electrical code 2009 be in a group of separate enclosures in a switchboard.

Philippine Electrical Code.pdf

Manually or Power Operable a Manually operable — A manually operable philippine electrical code 2009 or circuit breaker shall be equipped with a handle or other suitable operating means. Rating of Service Disconnecting Means: Tap Conductor — A conductor, other than a service conductor, that has overcurrent protection ahead of its point of supply that exceeds the value permitted for similar conductors that are protected.

Standard Ampere Ratings — The standard ampere ratings for fuses and inverse time circuit breakers shall be considered 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90,, philippine electrical code 2009,,,,,and amperes.

Additional standard ampere ratings for fuses shall be 1, 3, 6, 10, and